Siemens A5E38508031 frequency converter transformer Hall sensor current detection

promotions

Hde Shopping Event

Sale_coupon_15

$309.00

99 in stock

99 in stock

  • store Pick up from the HDE Store

Located in:Xi'an City China

  • delivery car Courier delivery

Our courier will deliver to the specified address

  • Courier delivery

DHL / Fedex / UPS / By Air 

Payment Methods:

payment methods

Basic information model: A5E38508031
Device type: Siemens Robbins High Voltage Inverter Closed Loop Hall Current Sensor
Adaptation system: Robbins 6kV/10kV high-voltage frequency converter power unit (such as 6SR4900 series), compatible with current levels of 200-300A power units
Core application: Real time collection of power unit output/DC bus current, converting high current into standard weak current signals for current closed-loop control, overcurrent protection, fault diagnosis, and ensuring stable operation of the frequency converter
Electrical parameter rated measurement current: 250A (AC/DC, continuous operation)
Measurement range: 0-300A (peak)
Output signal: DC 0-5V (linearly corresponding to 0-250A)
Power supply: DC ± 15V, rated current 0.1A
Accuracy level: ± 0.5% FS (full range)
Response time: ≤ 1 μ s
Isolation voltage: AC 2500V (primary secondary)
Temperature coefficient: ≤ 50 ppm/℃
Physical and environmental parameter structure form: onboard installation, compatible with Robbins standard power unit card slot
Protection level: IP20 (to be installed inside the power unit cabinet)
Working temperature: -25 ℃ -85 ℃
Storage temperature: -40 ℃ -100 ℃
Cooling method: Natural heat dissipation (assisted by power unit air ducts for heat dissipation)
Dimensions: Approximately 80mm x 60mm x 40mm (length x width x height)
Weight: Approximately 0.3kg
Adaptation and functional adaptation components: Robbins 6SR4900 series power unit, high-voltage inverter control unit
Functional features: electrical isolation, overcurrent threshold alarm, short circuit protection, temperature compensation
Installation requirements: Installed on the DC bus or output side of the power unit, firmly wired to avoid electromagnetic interference

Siemens A5E38508031 frequency converter transformer Hall sensor current detection Specifications

Basic information modelA5E38508031
Device typeSiemens Robbins High Voltage Inverter Closed Loop Hall Current Sensor
Measurement range0-300A (peak)
Output signalDC 0-5V (linearly corresponding to 0-250A)
Power supplyDC ± 15V, rated current 0.1A
Accuracy level± 0.5% FS (full range)
Response time≤ 1 μ s
Isolation voltageAC 2500V (primary secondary)
Temperature coefficient≤ 50 ppm/℃
Protection levelIP20 (to be installed inside the power unit cabinet)
Working temperature-25 ℃ -85 ℃
Storage temperature-40 ℃ -100 ℃
Cooling methodNatural heat dissipation (assisted by power unit air ducts for heat dissipation)
DimensionsApproximately 80mm x 60mm x 40mm (length x width x height)
WeightApproximately 0.3kg
Functional featureselectrical isolation, overcurrent threshold alarm, short circuit protection, temperature compensation
Installation requirementsInstalled on the DC bus or output side of the power unit, firmly wired to avoid electromagnetic interference

About the Siemens A5E38508031 frequency converter transformer Hall sensor current detection

The Siemens A5E38508031 frequency converter transformer Hall sensor current detection is a oil drilling equipment used in industrial automation, control and power systems. It is rated at Basic information model A5E38508031, Device type Siemens Robbins High Voltage Inverter Closed Loop Hall Current Sensor, Measurement range 0-300A (peak). This oil drilling equipment is supplied as new, original industrial-grade stock. Each unit is identified by manufacturer part number Siemens A5E38508031 frequency converter transformer Hall sensor current detection for accurate procurement and cross-referencing.

Why source the Siemens A5E38508031 frequency converter transformer Hall sensor current detection from HDE123

  • Verified part number: every Siemens A5E38508031 frequency converter transformer Hall sensor current detection is checked against its manufacturer specification before shipment.
  • 17 confirmed technical parameters available on this page for engineering review.
  • Global delivery with clear lead time and commercial invoice for B2B buyers.
  • Fast B2B support: send us the equipment model or an existing part number and our engineers confirm compatibility before you order.

Ordering the Siemens A5E38508031 frequency converter transformer Hall sensor current detection

To order the Siemens A5E38508031 frequency converter transformer Hall sensor current detection, add it to your cart and complete checkout, or use the Request a Quote form for volume purchases and replacement / cross-reference enquiries. Lead time: typically 3–10 working days for in-stock items, subject to confirmation. Worldwide shipping is available and a commercial invoice is provided for customs.