A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board

promotions

Hde Shopping Event

Sale_coupon_15

$206.00

99 in stock

99 in stock

  • store Pick up from the HDE Store

Located in:Xi'an City China

  • delivery car Courier delivery

Our courier will deliver to the specified address

  • Courier delivery

DHL / Fedex / UPS / By Air 

Payment Methods:

payment methods

Basic information model: A5E02268102
Device type: Siemens MM440 series frequency converter surge filter/rectifier absorption board
Compatible models: MM440 45kW, 55kW, 75kW (380-480V, compatible with current of about 90A-150A power module)
Core application: Suppress surge voltage on the grid side, absorb rectifier bridge shutdown spikes, protect the power module and control circuit of the frequency converter, and improve the EMC performance of the system
Electrical parameters Operating voltage: three-phase 380-480V AC, compatible with 50/60Hz power grid
Surge suppression level: line to line: differential mode 10kV, line to ground: common mode 15kV
Absorbing element: High voltage non inductive capacitor (about 10 μ F/1200V)+silicon carbide varistor (MOV) combination
Rated current: Continuous operating current 10A (peak value under surge conditions can reach 2000A/2ms)
Interface type: three-phase input terminal (compatible with MM440 standard incoming copper busbar), DC output terminal (connected to the DC side of the rectifier bridge)
Protection functions: overvoltage protection, overcurrent protection, component overheating protection
Physical and environmental parameter structure form: onboard installation, compatible with MM440 standard power unit card slot
Protection level: IP20 (to be installed inside the frequency converter cabinet)
Working temperature: -10 ℃ -50 ℃
Storage temperature: -25 ℃ -70 ℃
Cooling method: Natural heat dissipation (relying on the air duct inside the inverter cabinet for auxiliary heat dissipation)
Dimensions: Approximately 220mm x 150mm x 40mm (width x height x depth)
Weight: Approximately 0.8kg
Adaptation and functional adaptation components: MM440 series 45kW -75kW power modules, rectifier bridge components
Functional features: differential/common mode surge suppression, rectification peak voltage absorption, EMC filtering, contactless signal output in fault state
Installation requirements: Installed between the input side of the frequency converter and the rectifier bridge, the wiring should be tightened to avoid looseness and heat generation

A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board Specifications

Basic information modelA5E02268102
Device typeSiemens MM440 series frequency converter surge filter/rectifier absorption board
Compatible modelsMM440 45kW, 55kW, 75kW (380-480V, compatible with current of about 90A-150A power module)
Electrical parameters Operating voltagethree-phase 380-480V AC, compatible with 50/60Hz power grid
Surge suppression levelline to line: differential mode 10kV, line to ground: common mode 15kV
Absorbing elementHigh voltage non inductive capacitor (about 10 μ F/1200V)+silicon carbide varistor (MOV) combination
Rated currentContinuous operating current 10A (peak value under surge conditions can reach 2000A/2ms)
Protection functionsovervoltage protection, overcurrent protection, component overheating protection
Protection levelIP20 (to be installed inside the frequency converter cabinet)
Working temperature-10 ℃ -50 ℃
Storage temperature-25 ℃ -70 ℃
Cooling methodNatural heat dissipation (relying on the air duct inside the inverter cabinet for auxiliary heat dissipation)
DimensionsApproximately 220mm x 150mm x 40mm (width x height x depth)
WeightApproximately 0.8kg

About the A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board

The A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board is a oil drilling equipment used in industrial automation, control and power systems. It is rated at Basic information model A5E02268102, Device type Siemens MM440 series frequency converter surge filter/rectifier absorption board, Compatible models MM440 45kW, 55kW, 75kW (380-480V, compatible with current of about 90A-150A power module). This oil drilling equipment is supplied as new, original industrial-grade stock. Each unit is identified by manufacturer part number A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board for accurate procurement and cross-referencing.

Why source the A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board from HDE123

  • Verified part number: every A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board is checked against its manufacturer specification before shipment.
  • 14 confirmed technical parameters available on this page for engineering review.
  • Global delivery with clear lead time and commercial invoice for B2B buyers.
  • Fast B2B support: send us the equipment model or an existing part number and our engineers confirm compatibility before you order.

Ordering the A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board

To order the A5E02268102 Siemens MM440 frequency converter brake board surge absorption board incoming board, add it to your cart and complete checkout, or use the Request a Quote form for volume purchases and replacement / cross-reference enquiries. Lead time: typically 3–10 working days for in-stock items, subject to confirmation. Worldwide shipping is available and a commercial invoice is provided for customs.