Rated continuous working pressure: 135 bar (13.5 MPa), standard offshore VRCS valve control hydraulic system
Static leakage test pressure for sealing cavity: 200 bar full cavity pressure inspection
Actuator stroke: 90° quarter-turn, single-acting spring reset emergency shutdown design
Applicable hydraulic medium: ISO VG32 / VG46 marine anti-wear hydraulic oil
Max allowable return oil back pressure: 10 bar