J: Output signal = 4–20mA DC two-wire + HART7 digital communication
E: E capsule; Measuring range −1 ~ +1 kPa, adjustable span 0.1 ~ 1 kPa (−4 ~ 4 inH₂O)web-materi…
S: Wetted material; 316L SS manifold + Hastelloy C-276 isolation diaphragm
5: Kidney blind flange without external 1/4” NPT process vent/drain ports
J: Manifold fasteners: 316 stainless steel bolts & nuts
9: Horizontal pipe mounting, high-pressure chamber on left side, process ports downward layout
1: Single 1/2” NPT female electrical cable entry
2: Integral backlit LCD local digital display with on-site parameter setting buttons
EN: Standard silicone filling fluid, factory linear calibration
NF21: NEPSI flameproof certification Ex db IIC T6 Gb, Class I hazardous drilling zone explosion-proofNEX Instru…